The quantum
molecular resonance scalpel

QMR

VESALIUS QUANTUM SMART

is an advanced generator for Otorhinolaryngology (ENT) and Maxillofacial Surgery. It has one standard monopolar output and two different bipolar S.M.A.R.T. outputs that allow two accessories to be connected at the same time. Besides, the surgeon can perform coagulation, debulk and vaporization of the tissue in any environment (dry or wet).

S.M.A.R.T. (SELF MONITORING AND RECOGNITION TECHNOLOGY)

It is an innovative feature on-board with the newest Vesalius product range. This technology allows a precise communication between Vesalius QUANTUM SMART device and the connected accessories. The user receives important information about the accessory status (ref. number, number of times it was used, etc.) that facilitates product identification and lifecycle management, avoiding the risk of accessory overuse.

Smart Accessories

Vesalius QUANTUM SMART has a wide range of accessories that allow effective use of the device in multiple surgical procedures: parotid gland, neck, larynx, tonsils, adenoids, OSA (Obstructive Sleep Apnea) and much more.

CUT

The CUT function generates a precise cut, induced by the breaking of molecular bonds. The properties of the QMR allow to preserve the fabric thanks to a low temperature and an extremely delicate incision.

COAG

The bipolar coagulation of Vesalius generators is recognized for precision and effectiveness. Differently from the standard electrosurgical high frequency devices (which cause the vessels collapse and tissue necrosis), Vesalius deploys a peculiar waveform (slightly out of resonance) that increases the temperature up to 63-65°C. This triggers the denaturation processes of fibrinogen which turns into fibrin and coagulates the blood, without thermal damage of vessels

FEATURES

  • Decreased intraoperative blood loss
  • No necrotic tissue or thermal damage
  • Automatic impedance control system
  • Quantized high frequency spectrum: 4-8-12-16 MHz
  • Precise removal of tissues in an almost bloodless areas
  • New contact quality monitoring system for split neutral electrodes
  • Double bipolar S.M.A.R.T output for two accessories connected at the same time

FIELDS OF APPLICATION

  • ENT
  • Maxillofacial Surgery

TECHNICAL DATA

MONOPOLAR output:

  • CUT 120W/330 Ω
  • BLEND 100W/330 Ω
  • COAG 70 W/330 Ω

TECHNICAL DATA

BIPOLAR function:

  • CUT 120W/100 Ω
  • BLEND 100W/100 Ω
  • COAG 70W/100 Ω
Surgeries with “VESALIUS QUANTUM SMART”

ENT - Turbinate reduction with QMR Vesalius Device

ENT Tonsillectomy with QMR Vesalius Device

ENT Adenoidectomy with QMR Vesalius Device (Gaslini Hospital)

ENT Adenoidectomy with QMR Vesalius Device (Gaslini Hospital)

ENT Adenoidectomy with QMR Vesalius Device (Gaslini Hospital)

ENT - Larinx Microsurgery with QMR Vesalius Device (Dr. Acquaviva, Ospedale San Camillo Forlanini)

ENT - Parotidectomy with QMR Vesalius Device (Dr. Acquaviva, Ospedale San Camillo Forlanini)

ENT - Chordal Neoformation with QMR Device (Dr. Acquaviva, Ospedale San Camillo Forlanini, Rome)

ENT Endoscopic RVT with QMR Surgical Device

ENT - Synechiolysis with QMR Vesalius Device

ENT - Adenoidectomy with QMR Vesalius Device

ORL - Decongestione Osteo Tubarica con il dispositivo a QMR Vesalius

Riduzione bipolare dei turbinati con bisturi a QMR Vesalius - 3D - Italiano

Bipolar Turbinate Reduction with QMR Vesalius Device - 3D - English

Turbinati gonfi, sinusiti, otiti - Chirurgia Mininvasiva con QMR Technology.

QMR in Surgety: VESALIUS Quantum Smart